ULTIMA MOS 5 HART
6
10.0 Device Specific Commands
The Device Specific commands are used strictly for the unique features of the ULTIMA MOS 5 and at the
discretion of MSA. They are described here in Section 10.0 and are summarized in Table 4.
10.1 Command #131: Do Abort
This command aborts calibration or gas check.
Request Data Bytes
Byte Format Description
None N/A N/A
Response Data Bytes
Byte Format Description
0 N/A N/A
Command-Specific Response Codes
Code Class Description
0 Success No Command-Specific Errors
1 - 15 Undefined
16 Error Access Restricted
17 -
127
Undefined
10.2 Command #136: Set Alarm Level
This command sets the Alarm level.
Request Data Bytes
Byte Format Description
0 Unsigned-8 Alarm level, % of FS
Response Data Bytes
Byte Format Description
0 Unsigned-8 Alarm level, % of FS
Command-Specific Response Codes
Code Class Description
0 Success No Command-Specific Errors
1 – 2 N/A Undefined
3 Error Passed Parameter Too Large
4 N/A Undefined